Shaung Xi
Print Baltic99   
IMO/VIN Callsign Flag Service Year
9457842 ICOX ITALY Freight Ship
Activity# Port Date Activity - Description Deficiencies
6407847 Baltimore, Maryland May 07, 18 Vessel Inspection - Approved Inspection
  4
SystemSubsystemCause
ElectricalLighting (emergency)Improper/Lack of Maintenance
DescriptionDue DateResolved
0683 - Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of power. The PSCO observed multiple emergency lights with inoperable bulbs. 17ac SOLAS 74 (2014 Cons.) III/11.4Yes
Resolved DateResolution
May 08, 18Received class report attesting to the repairs. (See attachement in documents)
SystemSubsystemCause
Construction/LoadlineMarkingsDesign Flaw
DescriptionDue DateResolved
1220 - The International Load Line Certificate shall not be delivered to the ship until the officer or surveyor has certified that the marks accurately and permanently indicated on the ships' side. PSCO observed two load lines indicated on the vessel's STBD side. 17ac ICLL Reg. 9Yes
Resolved DateResolution
May 08, 18Received class report attesting to the repairs. (See attachement in documents)
SystemSubsystemCause
Operations/ManagementVessel Safety ManagementImproper/Lack of Maintenance
DescriptionDue DateResolved
1575 - If, during a voyage any equipment required by this part stops working properly, the person directing the movement of the vessel must report that it's not working properly to the nearest COTP as soon as possible. During current voyage the vessel's echo depth sounder stopped operating properly. PSCO determined that the vessel failed to report the inoperable depth sounder to the COTP. 10. 33 CFR 164.53(b)May 07, 18Yes
Resolved DateResolution
May 07, 18PSCO educated the vessel on when and how to request a LOD.
SystemSubsystemCause
NavigationCollision/Grounding AvoidanceImproper/Lack of Maintenance
DescriptionDue DateResolved
1575 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship, in all respects, will remain fit to proceed to sea without damage to the ship or persons on board. PSCO found the vessel's echo depth sounder inoperable. 17ac SOLAS 74 (2014 Cons.) I/11.aYes
Resolved DateResolution
May 08, 18Received class report attesting to the repairs. (See attachement in documents)
6061166 Portsmouth, Virginia Dec 22, 16 Vessel Operational Control - Agency Action Complete
5862903 Portsmouth, Virginia Apr 26, 16 Vessel Inspection - Approved Inspection
5058289 Baltimore, Maryland Jan 24, 15 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Operations/ManagementPollution
DescriptionDue DateResolved
2100: The sulfur content of fuel oil used in the North American ECA shall not exceed .10%. The vessel ran out of .10% fuel causing it to operate in the North American ECA w/ non-compliant fuel. MARPOL 2011 Cons. VI/15.4: 10cYes
Resolved DateResolution
Jan 24, 15Corrected on the spot. Vessel bunkered while in Baltimore.
4289288 Portsmouth, Virginia Apr 18, 12 Vessel Inspection - Approved Inspection
3923395 Baltimore, Maryland Jan 09, 11 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Classification Document October 29,2015 September 20,2020 RINA
International Load Line Certificate October 13,2015 September 20,2020 RINA
International Oil Pollution Prevention Certificate October 13,2015 September 20,2020 RINA
ISM - Document Of Compliance May 27,2010 March 19,2011 IT
ISM - Safety Management Certificate December 11,2015 December 16,2020 IT
Minimum Safe Manning Document December 1,2011 November 30,2012 IT
SOLAS Cargo Ship Safety Construction Certificate October 15,2015 September 20,2020 RINA
SOLAS Cargo Ship Safety Equipment Certificate September 22,2010 September 19,2012 IT
SOLAS Cargo Ship Safety Radio Certificate September 28,2017 September 21,2018 IT
Tonnage Certificate, International January 17,2011 IT