IMO/VIN
Callsign
Flag
Service
Year
9498236
3XEX2
LIBERIA
Freight Ship
2010
Activity#
Port
Date
Activity - Description
Deficiencies
7095166
MASSENA, New York
Nov 14, 20
Vessel Inspection - Approved Inspection
7067494
MASSENA, New York
Sep 29, 20
Vessel Inspection - Approved Inspection
6950761
DETROIT, Michigan
May 09, 20
Boarding - Agency Action Complete
6703102
MASSENA, New York
May 25, 19
Vessel Inspection - Agency Action Complete
6611120
Portsmouth, Virginia
Jan 23, 19
Vessel Inspection - Approved Inspection
4
0
System Subsystem Cause 03 - Water/Weathertight Conditions N/A - No Subsystem Improper/Lack of Maintenance
Description Due Date Resolved 03104 - Water/weathertight conditons - All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel or other equivalent material. Permanently and strong attached to bulkhead and framed, stiffened and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead and watertight when closed. PSCO observed foam around entire weather tight forward door to cargo hold number one. ICLL ANNEX I 12(1). Yes
Resolved Date Resolution Jan 26, 19 Vessel submitted class report attesting to corrective measures. See attached.
System Subsystem Cause 07 - Fire Safety N/A - No Subsystem
Description Due Date Resolved 07105 - Fire Safety - The following fire protection systems shall be kept in good order so as to ensure the required performance if a fire occurs. PSCO observed three self-closing fire doors as per ships fire control plan, that were not closing properly. One door in the oil purifier room and two doors leading to engine room escape routes. Also, fire door in main stairwell on "B" deck is not self-closing. 74 SOLAS (14) II-2/14.2.1.1.1 Yes
Resolved Date Resolution Jan 26, 19 Vessel submitted class report attesting to corrective measures. See attached.
System Subsystem Cause 07 - Fire Safety N/A - No Subsystem Improper/Lack of Maintenance
Description Due Date Resolved 07106 - Fire Safety - Fire detection systems shall be kept in good working order so as to ensure their required performance if a fire occurs. Smoke detector in engine control room space faulted when tested. 74 SOLAS (14) II-2/14.2.1.1 Yes
Resolved Date Resolution Jan 23, 19 Fire detector was replaced and tested satisfactory.
System Subsystem Cause 11 - Life Saving Appliances N/A - No Subsystem Improper/Lack of Maintenance
Description Due Date Resolved 11104 - Life Saving Appliances - Rescue boats shall be stowed in a state of continuous readiness for launching in not more than five minutes. PSCO observed the rescue engine unable to be started. 74 SOLAS (14) III/14.1 Yes
Resolved Date Resolution Jan 26, 19 Vessel submitted class report attesting to corrective measures. See attached.
6612650
Portsmouth, Virginia
Jan 20, 19
Vessel Operational Control - Approved Inspection
6423404
MASSENA, New York
May 22, 18
Vessel Inspection - Agency Action Complete
6325088
Jacksonville, Florida
Dec 22, 17
Vessel Inspection - Approved Inspection
6052509
Duluth, Minnesota
Dec 05, 16
Vessel Inspection - Agency Action Complete
6042311
MASSENA, New York
Nov 15, 16
Vessel Inspection - Approved Inspection
5176722
TOLEDO, Ohio
Jul 07, 15
Vessel Inspection - Approved Inspection
5156173
MASSENA, New York
Jun 14, 15
Vessel Inspection - Approved Inspection
5002776
MASSENA, New York
Oct 09, 14
Vessel Inspection - Approved Inspection
4946738
SAULT STE MARIE, Michigan
Aug 06, 14
Boarding - Agency Action Complete
4840060
MASSENA, New York
Apr 20, 14
Vessel Inspection - Approved Inspection
4705610
MASSENA, New York
Sep 01, 13
Vessel Inspection - Approved Inspection
4699987
TOLEDO, Ohio
Aug 29, 13
Vessel Inspection - Approved Inspection
4630036
SAULT STE MARIE, Michigan
Jun 15, 13
Boarding - Agency Action Complete
4604960
MASSENA, New York
May 28, 13
Vessel Inspection - Approved Inspection
4596525
WASHINGTON, District of Columbia
Nov 15, 12
Incident Investigation - Agency Action Complete
4320648
Duluth, Minnesota
May 24, 12
Vessel Inspection - Approved Inspection
4315257
TOLEDO, Ohio
May 18, 12
Boarding - Agency Action Complete
4183206
DETROIT, Michigan
Nov 06, 11
Boarding - Agency Action Complete
4011769
Duluth, Minnesota
May 18, 11
Vessel Inspection - Approved Inspection
2
0
System Subsystem Cause Lifesaving Inflatable Liferafts
Description Due Date Resolved Every liferaft shall be stowed with its painter permanately attached to the ship. The painter was not attached to the ship. May 18, 11 Yes
Resolved Date Resolution May 18, 11 Witnessed crew attach painter properly to the ship during the inspection.
System Subsystem Cause Construction/Loadline Markings Improper/Lack of Maintenance
Description Due Date Resolved The International Loadline Certificate shall not be delivered to the ship until it is certified that the marks are correctly and permenately indicated on the ships side. The Issuing Authority's initials were not permanately indicated on the hull. Yes
Resolved Date Resolution May 24, 12 M/V EMILIE provided copy of load line certificate to inspection team and verified with markings on the side of the hull.
4012842
Sault Ste Marie, Michigan
May 16, 11
Boarding - Agency Action Complete
4000808
MASSENA, New York
May 02, 11
Vessel Inspection - Approved Inspection
Documents
Issued
Expires
Agency
Certificate of Compliance - Pass./Freight Vessel
February 11,2011
November 8,2015
LR
Classification Document
December 22,2015
September 8,2020
LR
International Load Line Certificate
December 22,2015
November 8,2020
LR
International Oil Pollution Prevention Certificate
December 22,2015
November 8,2020
LR
ISM - Document Of Compliance
April 8,2011
May 3,2016
BV
ISM - Safety Management Certificate
July 14,2016
May 26,2021
NKK
Minimum Safe Manning Document
November 4,2016
LR
SOLAS Cargo Ship Safety Construction Certificate
December 22,2015
November 8,2020
LR
SOLAS Cargo Ship Safety Equipment Certificate
January 30,2016
November 8,2020
LR
SOLAS Cargo Ship Safety Radio Certificate
December 22,2015
November 8,2020
LR
Tonnage Certificate, International
March 10,2016
LR