Print Baltic99   
IMO/VIN Callsign Flag Service Year
9498236 3XEX2 LIBERIA Freight Ship 2010
Activity# Port Date Activity - Description Deficiencies
7095166 MASSENA, New York Nov 14, 20 Vessel Inspection - Approved Inspection
7067494 MASSENA, New York Sep 29, 20 Vessel Inspection - Approved Inspection
6950761 DETROIT, Michigan May 09, 20 Boarding - Agency Action Complete
6703102 MASSENA, New York May 25, 19 Vessel Inspection - Agency Action Complete
6611120 Portsmouth, Virginia Jan 23, 19 Vessel Inspection - Approved Inspection
  4
SystemSubsystemCause
03 - Water/Weathertight ConditionsN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
03104 - Water/weathertight conditons - All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel or other equivalent material. Permanently and strong attached to bulkhead and framed, stiffened and fitted so that the whole structure is of equivalent strength to the unpierced bulkhead and watertight when closed. PSCO observed foam around entire weather tight forward door to cargo hold number one. ICLL ANNEX I 12(1).Yes
Resolved DateResolution
Jan 26, 19Vessel submitted class report attesting to corrective measures. See attached.
SystemSubsystemCause
07 - Fire SafetyN/A - No Subsystem
DescriptionDue DateResolved
07105 - Fire Safety - The following fire protection systems shall be kept in good order so as to ensure the required performance if a fire occurs. PSCO observed three self-closing fire doors as per ships fire control plan, that were not closing properly. One door in the oil purifier room and two doors leading to engine room escape routes. Also, fire door in main stairwell on "B" deck is not self-closing. 74 SOLAS (14) II-2/14.2.1.1.1Yes
Resolved DateResolution
Jan 26, 19Vessel submitted class report attesting to corrective measures. See attached.
SystemSubsystemCause
07 - Fire SafetyN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
07106 - Fire Safety - Fire detection systems shall be kept in good working order so as to ensure their required performance if a fire occurs. Smoke detector in engine control room space faulted when tested. 74 SOLAS (14) II-2/14.2.1.1Yes
Resolved DateResolution
Jan 23, 19Fire detector was replaced and tested satisfactory.
SystemSubsystemCause
11 - Life Saving AppliancesN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
11104 - Life Saving Appliances - Rescue boats shall be stowed in a state of continuous readiness for launching in not more than five minutes. PSCO observed the rescue engine unable to be started. 74 SOLAS (14) III/14.1Yes
Resolved DateResolution
Jan 26, 19Vessel submitted class report attesting to corrective measures. See attached.
6612650 Portsmouth, Virginia Jan 20, 19 Vessel Operational Control - Approved Inspection
6423404 MASSENA, New York May 22, 18 Vessel Inspection - Agency Action Complete
6325088 Jacksonville, Florida Dec 22, 17 Vessel Inspection - Approved Inspection
6052509 Duluth, Minnesota Dec 05, 16 Vessel Inspection - Agency Action Complete
6042311 MASSENA, New York Nov 15, 16 Vessel Inspection - Approved Inspection
5176722 TOLEDO, Ohio Jul 07, 15 Vessel Inspection - Approved Inspection
5156173 MASSENA, New York Jun 14, 15 Vessel Inspection - Approved Inspection
5002776 MASSENA, New York Oct 09, 14 Vessel Inspection - Approved Inspection
4946738 SAULT STE MARIE, Michigan Aug 06, 14 Boarding - Agency Action Complete
4840060 MASSENA, New York Apr 20, 14 Vessel Inspection - Approved Inspection
4705610 MASSENA, New York Sep 01, 13 Vessel Inspection - Approved Inspection
4699987 TOLEDO, Ohio Aug 29, 13 Vessel Inspection - Approved Inspection
4630036 SAULT STE MARIE, Michigan Jun 15, 13 Boarding - Agency Action Complete
4604960 MASSENA, New York May 28, 13 Vessel Inspection - Approved Inspection
4596525 WASHINGTON, District of Columbia Nov 15, 12 Incident Investigation - Agency Action Complete
4320648 Duluth, Minnesota May 24, 12 Vessel Inspection - Approved Inspection
4315257 TOLEDO, Ohio May 18, 12 Boarding - Agency Action Complete
4183206 DETROIT, Michigan Nov 06, 11 Boarding - Agency Action Complete
4011769 Duluth, Minnesota May 18, 11 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
LifesavingInflatable Liferafts
DescriptionDue DateResolved
Every liferaft shall be stowed with its painter permanately attached to the ship. The painter was not attached to the ship.May 18, 11Yes
Resolved DateResolution
May 18, 11Witnessed crew attach painter properly to the ship during the inspection.
SystemSubsystemCause
Construction/LoadlineMarkingsImproper/Lack of Maintenance
DescriptionDue DateResolved
The International Loadline Certificate shall not be delivered to the ship until it is certified that the marks are correctly and permenately indicated on the ships side. The Issuing Authority's initials were not permanately indicated on the hull.Yes
Resolved DateResolution
May 24, 12M/V EMILIE provided copy of load line certificate to inspection team and verified with markings on the side of the hull.
4012842 Sault Ste Marie, Michigan May 16, 11 Boarding - Agency Action Complete
4000808 MASSENA, New York May 02, 11 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Certificate of Compliance - Pass./Freight Vessel February 11,2011 November 8,2015 LR
Classification Document December 22,2015 September 8,2020 LR
International Load Line Certificate December 22,2015 November 8,2020 LR
International Oil Pollution Prevention Certificate December 22,2015 November 8,2020 LR
ISM - Document Of Compliance April 8,2011 May 3,2016 BV
ISM - Safety Management Certificate July 14,2016 May 26,2021 NKK
Minimum Safe Manning Document November 4,2016 LR
SOLAS Cargo Ship Safety Construction Certificate December 22,2015 November 8,2020 LR
SOLAS Cargo Ship Safety Equipment Certificate January 30,2016 November 8,2020 LR
SOLAS Cargo Ship Safety Radio Certificate December 22,2015 November 8,2020 LR
Tonnage Certificate, International March 10,2016 LR