Teal Bulker
Print Baltic99   
IMO/VIN Callsign Flag Service Year
9668908 3FTV3 PANAMA Freight Ship 2014
Activity# Port Date Activity - Description Deficiencies
6869454 New Orleans, Louisiana Dec 08, 19 Vessel Inspection - Administrative Action
6612352 New Orleans, Louisiana Feb 07, 19 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
10 - Safety of NavigationN/A - No Subsystem
DescriptionDue DateResolved
01-10104-All ships of 500 GT and upwards shall, in addition to meeting the requirements of paragraph 2.3, with the exception of paragraphs 2.3.3 and 2.3.5, and the requirements of paragraph 2.4, have: a gyrocompass heading repeater, or other means, to supply heading information visually at the emergency steering position. The gyrocompass repeater in the steering gear compartment displayed an error of 44 degrees.Feb 07, 19Yes
Resolved DateResolution
Feb 08, 19Recieved documentation of repair from Classification Society satisfying the regulation.
SystemSubsystemCause
11 - Life Saving AppliancesN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Before the ship leaves port and at all times during the voyage, all life saving applicances shall be in working order and ready for immediate use. The rescue boat davit repeatedly tripped the breaker during operation and was incapable of slewing the rescue boat right or left.Feb 07, 19Yes
Resolved DateResolution
Feb 08, 19Recieved documentation of repair from Classification Society satisfying the regulation.
6317437 BOSTON, Massachusetts Dec 05, 17 Vessel Inspection - Approved Inspection
5760283 PHILADELPHIA, Pennsylvania Nov 09, 15 Vessel Inspection - Approved Inspection
5090535 BOSTON, Massachusetts Mar 25, 15 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Operations/ManagementVessel Safety Management
DescriptionDue DateResolved
2500 - ISM Related deficiencies - Procedures need to be established. Tested smoke detector in purifier room activating the water mist system because it was left in the automatic mode. There is no procedure established to ensure system is in manual when detectors are tested and returned to auto mode after tests are complete. 74 SOLAS (15 cons.) IX/3.1 & ISM Code 10.1Yes
Resolved DateResolution
Mar 30, 15Received, acknowledged, and reviewed report from RO confirming rectification of deficiency issued by Sector Boston. Procedures for testing smoke detectors were updated and placed in the appropriate position. See attached documents.
Documents Issued Expires Agency
Classification Document July 28,2014 April 29,2019 NKK
International Load Line Certificate July 1,2014 April 29,2019 NKK
International Oil Pollution Prevention Certificate September 12,2014 April 29,2019 NKK
ISM - Document Of Compliance July 28,2017 November 14,2020 N/A
ISM - Safety Management Certificate July 28,2017 September 29,2019 NKK
Minimum Safe Manning Document March 28,2014 PA
SOLAS Cargo Ship Safety Construction Certificate July 1,2014 April 29,2019 NKK
SOLAS Cargo Ship Safety Equipment Certificate July 6,2017 April 29,2019 NKK
SOLAS Cargo Ship Safety Radio Certificate March 2,2018 April 29,2019 NKK
Tonnage Certificate, International April 30,2014 NKK